Polímeros: Ciência e Tecnologia
https://revistapolimeros.org.br/doi/10.4322/polimeros.2013.063
Polímeros: Ciência e Tecnologia
Scientific & Technical Article

Qualitative histologic evaluation of the tissue reaction to the Polyurethane resin (Ricinus communis – based biopolymer) implantation assessed by light and scanning electron microscopy

Belmonte, Gustavo Campos; Catanzaro-Guimarães, Sergio Augusto; Sousa, Tatiana Peixoto T. de; Carvalho, Renato Savi; Kinoshita, Angela

Downloads: 0
Views: 1101

Abstract

The tissue reaction of bone tissue accessed by light microscopy and scanning electron microscopy (SEM) images after polyurethane resin implantation is presented in the present study. Twenty four male rabbits were used, divided into two groups of 12 animals each (experimental group and control group) in which fulll-thickness cranial defect was surgically created. At 30 and 90 days postoperatively 6 animals of each group were euthanized and bone samples were removed to analysis. The microscopic results indicated no inflammatory foreign body reaction, a perfect union between the polymer and surgical bone bed surface, lack of bone resorption and presence of a thin layer of osteogenic material covering the polymer surface in contact with the surgical bone bed. The SEM images demonstrate the porosity of the resin, with diameters from 120 to 500um. This important feature of this polymer is associated with its osteocondutivity, allowing the bone growth inside it, improving the integration between the material and bone tissue. So the results of this work reinforce that polyurethane resine derived from Ricinus communis is an excellent bone substitute for use in great bone losses repair surgery.

Keywords

Bone repair, Polyurethane resin, Osteoconduction, Biocompatibility

References

[1] Schmitz, J.P.; Hollinger, J.O. - Clin Orthop Rel Res, 205, p. 299 – 308 (1986)

[2] Kawamura, M.; Urist, M.R. - Clin Orthop Rel Res, 236, p. 240 – 248 (1988)

[3] Mardas, N.; Kostopoulos, L.; Karring, T. - J Craniof Surg 13 (3), p.453-462 (2002)

[4] Haddad, A.J.; Peel, S.A.F.; Clokie, C.M.L. et al.. - J Craniof Surg 17(5), p.926- 934 (2002)

[5] Jensen, S.S.; Aaboe, M.; Pinholt, E.M. et al -. Int J Oral Maxillofac Implants 11(1), p. 55 – 66 (1996)

[6] Jensen OT. “Guided Bone Graft Augmentation”. In: Guided Bone Regeneration in Implant Dentistr, Buser D, Dahlin C, Schenck RK. eds.. Chicago, Quintessence (1994).

[7] Arrington, E.D.; Smith, W.J.; Chanbers HG et al - Clin Orthop Rel Res 329, p.300 – 309 (1996)

[8] Friedlaender, G.E. - J Bone Joint Surg Am 69(5), p. 786 – 790 (1987)

[9] Goldberg, V.M.; Stevenson, S. - Clin Orthop Rel Res 225, p.7 – 16 (1987)

[10] Buck, B.E.; Malinin, T.I.; Brown, M.D.- Clin Orthop Rel Res 240, p. 129 – 136 (1989)

[11] Chapman, P.G.; Villar, R.N. - J Bone Joint Surg Br 74(3), p.398 – 399 (1992)

[12] Calvo-Guirado, J. L.; Delgado-Ruiz, R. A.; Ramirez-Fernandez, M. P.; Mate- Sanchez, J.E.; Ortiz-Ruiz, A.; Marcus, A. - Clin Oral Impl Res, 23(6), p.667- 675 (2012)

[13] Kim, H.J.; Park, I.K.; Kim,J.H.; Cho, C.S.;Kim, M.S. - Tissue Engineering and Regenerative Medicine, 9(2), p, 63-68 (2012)

[14] Huang, X.; Miao, X. - J Biomater Appl 2007; 21(4):351-374.

[15] Pereira Jr, O.C.M.; Rahal, S.C.; Iamaguti, P. et al. - J Biomater Appl 21(3), p.283-297 (2007)

[16] Ereno, C.; Guimarães, S. A. C.; Pasetto, S.; Herculano, R. D.; Silva, C. P.; Graeff, C. F. O.; Tavano, O.; Baffa, O.; Kinoshita, A. - Journal of Biomedical Materials Research Part A 95A (3), p.932-939 (2010)

[17] Herculano, R. D.; Silva, C. P.; Ereno, C.; Guimaraes, S. A. C.; Kinoshita, A.; Graeff, C. F. O. - Materials Research 12, 253-256 (2009)

[18] Matsumoto, M.A.; Caviquioli, G.; Briguetti, C.C.; Holgado, L.A.; Saraiva, P.P.; Muniz-Renno, A.C.; Kawakami, R.Y.-Journal of Materials Science- Materials in Medicine 23(6), p.1447-1456 (2012)

[19] Wu, C.; Luo, Y.; Cuniberti, G.; Xiao, Y.; Gelinsky, M. - Acta Biomaterilia, 7(6), p.2644-2650 (2011)

[20] Rahman, C.V.; Saeed, A.; White, L.J., Gould, T.W.A.; Kirby, G.T.S.; Sawkins, M.J.; Alexander, C.; Rose, F.R.A.J. and Shakesheff, K.M. Chemistry of Materials 24(5), p.781-795 (2011).

[21] Asefnejad, A; Behnamghader, A.; Khorasani, M.T. - International Journal of Nanomedicine, 6(1), p.93-100 (2011).

[22] Kim, H.; Park, I.; Kim, J.; Cho, C. and Kim, M. - Tissue Eng Regen Med 9(2), p.63-68.(2012)

[23] Li, B.; Brown, K.V.; Wenke, J.C. and Guelcher, S.A. Journal of Controlled Release 145(3), p.221-230 (2010)

[24] Jerald ED, Pamela BB, Edna MP, Teja G, Robert GH, Joseph CW, and Scott AG. 2012. Biomed Mater 7(2):024112. (2012)

[25] http://www.poliquil.com.br/ accessed December 18, 2012.

[26] Barros, V.M., Rosa, A.L., Beloti, M.M. and Chierice, G. J Biomed Mater Res A 67(1), p.235-239 (2003)

[27] Dahlin, C. “Scientific background of guided bone regeneration”. in: Guided bone regeneration in implant dentistry Buser, D.; Dahlin, C.; Schenck, R.K. eds.. Chicago: Quintessence, p. 31-48 (1994)

[28] Schlegel, K.A.; Sindet-Pedersen, S.; Hoepffner, H.J. - J Biomed Mater Res, 53(4) p.392 – 399. (2000)

[29] Carvalho, T.L.; Teofilo, J.M.; Araújo, C.A. et al - J Biomed Mater Res, 37(4) p.449-452.

[30] Dumas, J.E.; BrownBaer, P.B; Prieto, E.M.; Guda,T.; Hale, R.G.; Wenke, J.C.; Guelcher, S.A. Biomedical Materials, 7(2), p.S1 (2012)

[31] Pascon, E.A.; Leonardo, M.R.; Safari, L.; Langeland, K. - Oral Surg Oral Med Oral Pathol, 72(2), p.222 – 237 (1991)

[32] Sutherland, D.; Bostron, M. “Grafts and bone graft substitutes” in Bone regeneration and repair. Biology and Clinical applications, Liebernam, J.R.; Friedlaender, G.E. eds. Totowa, New Jersey: Humana Press; p. 133-156 (2005)

[33] Klawitter, J.J.; Bagwell, J.G.; Weinstein, A.M. et al.- J Biomed Mater Res, 10(2), p.311 – 323 (1976)

[34] Daculsi, G.; Passuti, N. – Biomaterials, 11, p. 86 – 87 (1990)

[35] Isaksson, S. - Swed Dent J Suppl, 84, p.1 – 46 (1992)

5883718e7f8c9d0a0c8b495f polimeros Articles
Links & Downloads

Polímeros: Ciência e Tecnologia

Share this page
Page Sections