Polímeros: Ciência e Tecnologia
https://revistapolimeros.org.br/doi/10.1590/S0104-14282004000300010?lang=en
Polímeros: Ciência e Tecnologia
Scientific & Technical Article

Imobilização de Proteínas do Veneno do Escorpião Tytius Serrulatus em Blenda Condutora de Polianilina-Poli(Metacrilato de Hidroxietila)

Proteins Associated with the Venom of the Tytius Serrulatus Scorpion Immobilized within Polyaniline-Poly(Hydroxyethyl Methacrylate) conducting blends

Bruno, Lívio; Barra, Guilherme; Mansur, Herman; Oréfice, Rodrigo L.

Downloads: 0
Views: 1074

Resumo

Biossensores têm a função de detectar e analisar tanto quantitativa como qualitativamente a presença de uma certa molécula em um determinado meio, isto com resposta em tempo real e sem etapas intermediárias de processo. Para isso, o biossensor possui sempre em seu conjunto um sistema de reconhecimento biológico que o diferencia de qualquer outro tipo de sensor. O objetivo deste trabalho foi desenvolver hidrogéis condutores a partir da combinação de polianilina com hidrogel poli(metacrilato de hidroxietila) e avaliar alguns aspectos associados à possível utilização deste como base de um biossensor capaz de detectar a presença de frações tóxicas do antígeno do veneno do escorpião Tytius Serrulatus. Hidrogéis condutores foram sintetizados a partir da mistura, em diferentes proporções, de polianilina e poli(metacrilato de hidroxietila) em um solvente comum. A condutividade elétrica (método de quatro pontas), capacidade de inchamento e morfologia (microscopia eletrônica de varredura) foram avaliadas para blendas com diferentes composições. Antígenos relativos ao veneno do escorpião Tytius Serrulatus foram incorporados às blendas condutoras a partir do inchamento dos hidrogéis por soluções aquosas contendo as moléculas de interesse. A imobilização e bioatividade das biomacromoléculas nos hidrogéis foram constatadas através de ensaio imunoabsorvente ELISA cujos resultados foram avaliados por espectroscopia na região do ultravioleta-vísivel. Os resultados mostraram que a incorporação de baixos conteúdos de Pani (20% em massa) em hidrogéis de poli(metacrilato de hidroxietila) foi suficiente para a produção de materiais com elevada condutividade elétrica e grande capacidade de inchamento. Moléculas associadas ao veneno do escorpião Tytius Serrulatus foram imobilizadas com sucesso nos hidrogéis condutores e mantiveram suas capacidades funcionais.

Palavras-chave

Biossensor, polianilina, blendas condutoras, escorpião

Abstract

Biosensors can detect and analyze quantitatively and qualitatively the presence of a given molecule in a specific environment. Biosensors always have a biological recognition system that distinguishes them from any other kind of sensor. The goals of this work were to develop conductive hydrogels from the combination of polyaniline and poly(hydroxyethyl methacrylate) and to evaluate some important aspects related to the possibility of using these materials as matrices in biosensors that would detect toxic fractions of antigens associated with the venom of the Tytius Serrulatus scorpion. Different conductive blends from poly(hydroxyethyl methacrylate) and polyaniline were produced by dissolving the polymers in a common solvent. The electrical conductivity, morphology and swelling ability were measured the four-probe measuring system, scanning electron microscopy and weight gain in water, respectively. Immobilization and bioactivity of molecules associated with the venom of the Tytius Serrulatus scorpion were evaluated by combining the ELISA immunoassay method and ultraviolet-visible spectroscopy. The results showed that even low concentrations of polyaniline led to high values of electrical conductivity and swelling. The biological tests indicated that the immobilization and bioactivity of the biomacromolecules associated with the venom of the Tytius Serrulatus scorpion were successfully achieved within the conductive hydrogel.

Keywords

Biosensor, polyaniline, conductive blends, scorpion

References



1. Collingst, A†., Caruso F. Rep. Prog. Phys 60 p.1397 – 1445 (1997)

2. Luppa, P. Clinica Chimica Acta 314 p.1 – 26 (2001)

3. Brahim, S. Biosensors & Bioeletronics, 17 p.53 – 59 (2002)

4. Lian Cen, K.G.. Biosensors & Bioeletronics, 18 p.363 – 374 (2003)

5. Revelo, M.P. Toxicon, 34 p.1119 – 1125 (1996)

6. Olortegui, C. Toxicon, 32 p.1649 – 1656 (1994)

7. Gerard, M. Biosensors & Bioeletronics, 17 p.345 – 359 (2002)

8. Sergeyeva, T. Sensors and Actuors B, 34 p.283 –288 (1996)

9. Duncan, A. C. European Polymer Journal, 37 p.1821 – 1826 (2001)

10. McDiarmid, A.G.; Chiang, J.D.; Richeter, A.F.; Somasiri, N.L.D.; Epstein, A.J. Conducting Polymers, in: Alcacer, L., cap 1, Reidel Pub (ed.), Dordrecht Holland, (1987).

11. Lowry, O. R. Journal Biology Chemisry, 193 p.265 – 275 (1951)

12. Banerjee P.; Mandal, B. M. Macromolecules 28 p.3949 (1995).

13. Stauffer, D. Introduction to Percolation theory, Taylor and Francis, London 1985.

14. Yang, C.Y. Synthetic Metal, 53 p.293 (1993).
588370f97f8c9d0a0c8b467b polimeros Articles
Links & Downloads

Polímeros: Ciência e Tecnologia

Share this page
Page Sections